Volume 16, Issue 2 (Iranian South Medical Journal 2013)                   Iran South Med J 2013, 16(2): 138-143 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Akaberian S, Vahedparast H, Ravanipour M, Mirzaei K. Comparison of Broselow tape measurements versus mother estimations of pediatric weights . Iran South Med J 2013; 16 (2) :138-143
URL: http://ismj.bpums.ac.ir/article-1-422-en.html
1- Department of Nursing, School of Nursing and Midwifery, Bushehr University of Medical Sciences, Bushehr, IRAN , sh.akabarian@bpums.ac.ir
2- Department of Nursing, School of Nursing and Midwifery, Bushehr University of Medical Sciences, Bushehr, IRAN
3- The Persian Gulf Tropical Medicine Research Center, The Persian Gulf Biomedical Research Center, Bushehr University of Medical Sceinecs, Bushehr, IRAN
4- Department of Community Medicine, School of Medicine, Bushehr University of Medical Sciences, Bushehr, IRAN
Abstract:   (9428 Views)

Background Pediatric resuscitation is challenging for therapeutic group. The most physicians have limited experience in dealing with this situation. Appropriate dosing of the drugs depends on the body weight of the children that it is usually not feasible. There is need for a fast, convenient and reliable method for body weight estimation in children. The aim of this study was to assess the accuracy of Broselow tape in children of Bushehr city. Material and Methods: This cross-sectional study was conducted in the emergency department of Aliasghar hospital. Children were between 1 month and 14 years. Children with chronic disease, 334, ill children were excluded from study. Estimated weight measured based on Broselow tape and actual weight measured by digital scale, then estimated and actual weight were compared. The results were analyzed by SPSS Software Ver 18 and T-Test, Chi-Square Test. Results: findings showed that 43.2% of total subjects were female Mean of age were 43 months. 72.5% of tape body weights were within  10% error of actual body weights. 78.9% of tape body weight was within  15% error of actual body weights. There was no significant difference between boys and girls. Conclusion: Broslow tape was easy, fast and exact for body weight estimation in emergency situation .it is more exact of body weight estimation by parents or therapeutic group so it helps therapeutic group in emergency department for accounting of medication dosage and equipment sizes.

Full-Text [PDF 129 kb]   (2235 Downloads)    
Type of Study: Original | Subject: General
Received: 2012/04/23 | Accepted: 2012/06/21 | Published: 2013/04/29

Send email to the article author


Rights and Permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 CC BY-NC 4.0 | Iranian South Medical Journal

Designed & Developed by: Yektaweb