Volume 17, Issue 3 (Iranian South Medical journal 2014)                   Iran South Med J 2014, 17(3): 443-450 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Elahifar M A, Dehghan Monfared G H, Ranjbar Sistani M. Assessment of radiographic film repeats rate and its causes in radiology centers of Zahedan University of medical sciences. Iran South Med J 2014; 17 (3) :443-450
URL: http://ismj.bpums.ac.ir/article-1-557-en.html
1- Department of Radiology, Ali Ebn Abitaleb Hospital, Zahedan University of Medical Sciences, Zahedan, IRAN
2- Department of Radiology, Ali Ebn Abitaleb Hospital, Zahedan University of Medical Sciences, Zahedan, IRAN , dm81464@yahoo.com
Abstract:   (6991 Views)

Background: In diagnostic radiology, analysis of set aside radiographic films is a useful method for testing quality control. Repeated radiography not only imposes additional costs, but also increases the amount of unnecessary radiation dose radiated to the patients and relevant staff. The aim of this study to determine the frequency of set aside radiographic films and its reasons. Materials and Methods: In this descriptive study, radiographic films were evaluated over a period of two months. After reviewing the scientific literature, a form was designed to study the setting aside of radiographic films and its related reasons. The results were analyzed using descriptive statistics. Results: A total of 24,392 radiographies were performed. The frequency of repeated radiographic films was 1241. The average rate of repeated radiographies in three hospitals was 5.09%. The specific rates of repeated radiographies in Khatamolanbia, Bu-Ali and Ali-ibn-e-Abitaleb Hospitals were 5.32%, 7.22%, and 2.75%, respectively. The main reasons for repeating radiography were radiation errors (42.72%) and the movement of patients (20.30%). The highest rate of repeating radiography was related to the pelvic cavity (11.72%). Conclusion: It was found that human error plays an important role in the repetition of radiographic images. Repetition rate of radiographic images in this study is in the middle range compared to the previous studies conducted in Iran, but its rate in some hospitals and some organs is not acceptable.

Full-Text [PDF 622 kb]   (1888 Downloads)    
Type of Study: Original | Subject: General
Received: 2012/12/7 | Accepted: 2013/02/19 | Published: 2014/06/15

Send email to the article author


Rights and Permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 CC BY-NC 4.0 | Iranian South Medical Journal

Designed & Developed by: Yektaweb