Survey of chemical quality and corrosion and scaling potential of drinking water distribution network of Bushehr city
Ghorban Asgari1, Bahman Ramavandi 2, Monereah Tarlaniazar3, Amir Fadaie nobandegani1, Zohreh Berizie1
1- Social Determinants of Health Research Center, Department of Environmental Health Engineering, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran
2- Department of Environmental Health Engineering, Faculty of Health, Bushehr University of Medical Sciences, Bushehr, Iran , ramavandi_b@yahoo.com
3- Department of Environmental Health Engineering, Faculty of Health, Shiraz University of Medical Sciences, Shiraz, Iran
Abstract:   (4011 Views)

Background: Determination of water corrosion indexes is one of the affecting approaches on drinking water management. Corrosion can causes economical problems, reduce the useful life of water facilities, and health damages to consumers. The aim of this study was to survey of chemical quality and determination of the corrosion potential of the water distribution system in Bushehr city. Materials and Methods: In this cross sectional study, the sampling was carried out during one year from 7 stations. Values of Langelier, Ryznar, corrosivity and Puckorius indexes were calculated by using such parameters as pH, total dissolved solids, temperature, permanent and temporary hardness, and alkalinity. Results: The average values for pH, total dissolved solids, temperature, and alkalinity was obtained 7.5, 586.82 mg/L, 66.92 mg/L CaCO3. The corrosion indexes were calculated Langelier 0.28, Ryznar 7.24, corrosivity 12.02, and Puckorius 7.81. Conclusion: Bushehr city water is tends to be slightly scaling based on Ryznar index and corrosive based on other studied indexes. Overall, the water quality was tending to corrosive and, therefore, recommended to use corrosion resistance pipes in water transmission and network or lining the inner wall of pipes or correction the water quality.

Keywords: Chemical quality, Corrosion index, Scaling, Bushehr
Full-Text [PDF 579 kb]   (1885 Downloads)    
Type of Study: Original | Subject: General
Received: 2015/05/3 | Accepted: 2015/05/3 | Published: 2015/05/3
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Asgari G, Ramavandi B, Tarlaniazar M, Fadaie nobandegani A, Berizie Z. Survey of chemical quality and corrosion and scaling potential of drinking water distribution network of Bushehr city. Iran South Med J. 2015; 18 (2) :353-361
URL: http://ismj.bpums.ac.ir/article-1-681-en.html


Volume 18, Issue 2 (Iranian South Medical Journal 2015) Back to browse issues page
دانشگاه علوم پزشکی بوشهر، طب جنوب ISMJ

Iranian South Medical Journal is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License which allows users to read,
copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly

Copyright © 2017, Iranian South Medical Journal| All Rights Reserved

Persian site map - English site map - Created in 0.05 seconds with 32 queries by YEKTAWEB 4137